Corrosion Inhibitor Multifunctional Closed Chilled Systems

SKU:
RXSOL-40-4011-025
Packing Sizes: 

Alkaline Corrosion Inhibitor blend for Metal protection inside the CLOSED circulating system. RXSOL closed water treatment chemicals are designed to treat hot and chilled water systems. The product contains a combination of nitrite, borate, and silicate formulated to minimize corrosion and deposition. Alkaline inhibitor for closed cooling systems available in 30 Kg Liquid and 220 Kg Drum PACKS.

Corrosion Inhibitor Additives for Water system
This is a Highly effective INHIBITOR for closed loop , line chilled water with unique dual control of corrosion and scale from system.

 

This closed water treatment chemicals are  designed to treat hot and chilled water systems. The product contains a combination of nitrite, borate, and silicate formulated to minimize corrosion and deposition. The product comes in a clear and pink appearance form.
 

RXSOL-40-4011-025 is a superior multifunctional, nitrite-based chemical treatment used for the control of corrosion in closed cooling systems and chilled water systems. RXSOL-40-4011-025 is a liquid product containing a combination of ferrous and non-ferrous corrosion inhibitors, a non-carbonate buffer, scale inhibitors, dispersants and a leak detection dye.

Product Application: 

RXSOL-40-4011-025 is a superior multifunctional, nitrite-based chemical treatment used for the control of corrosion in closed cooling systems and chilled water systems. RXSOL-40-4011-025 is a liquid product containing a combination of ferrous and non-ferrous corrosion inhibitors, a non-carbonate buffer, scale inhibitors, dispersants and a leak detection dye.

Product Dose: 

Compatible with Feeders, piping and valves should be made of steel, polyethylene, or PVC. This Treatment can be controlled by a nitrite test.

The recommended dosage of RXSOL-40-4011-025 is 15.6-23.4 l/m3 of system capacity or 60.6-87 RXSOL-40-4011-025 of system capacity in all systems. Clean up the system if the system becomes contaminated with iron. Maintain 600-750 ppm nitrite as NO2. RXSOL-40-4011-025  is intended for industrial use only. It should not be fed to potable water systems

Product Note: 

◦Very effective to Controls corrosion on brass, aluminum, steel, and stainless steel
◦Extends equipment life & Improves overall equipment efficiency

Product Technical Specification: 

Corrosion Inhibitor Additives for Water system
This is a Highly effective INHIBITOR for closed loop , line chilled water with unique dual control of corrosion and scale from system.

This closed water treatment chemicals are  designed to treat hot and chilled water systems. The product contains a combination of nitrite, borate, and silicate formulated to minimize corrosion and deposition. The product comes in a clear and pink appearance form.

Remarks: 

Keep in a tightly closed container in storage closed area . Recommended storage temperature is below 500C
 

Distributor: 
DUBICHEM is Popular Water Treatment Chemicals supplier in Mussafah Industrial Area Abu Dhabi, Dubai, Sharjah, Ajman, Fujairah, United Arab Emirates. Corrosion Inhibitor Multifunctional Closed Chilled Systems Emirates. Formation of Scale and Corrosion not only damaging Equipment and machicnery pipeling, But also increasing down time Maintenance Time. RXSOL CORROSION INHIBITOR for cooling System is new generation cooling water Treatment Product.
 
RXSOL Corrosion Inhibitor Additives for Cooling Water system : This is a Highly effective INHIBITOR for closed loop , line chilled water with unique dual control of corrosion and scale from system. 
 
#CoolingWaterTreatmentCHemicals
#CorrosionInhibitor_WaterTreatmentChemical
Manufacturer: 

Water Treatment Chemical Manufacturer in Mussafah Industrial Area Abu Dhabi, Dubai, Sharjah, Ajman, Fujairah, United Arab Emirates.

Cooling Water Corrosion Inhibitor

Why RXSOL CORROSION INHIBITOR for cooling Water System Required ?

Corrosion damage metal surface by chemical or electrochemical reaction which results failure of equipment with the resultant cost of replacement and plant downtime.

Due to Deposition of  CORROSION  result fouling in of heat exchanger fouling caused by the accumulation of corrosion products., Heat Transfer efficiency decreases. Which resulting loss of plant efficiency due to loss of heat transfer.
 

HOW to CONTROL CORROSION in COOLING SYSTEM?
 
Primary Step : Use calcium carbonate bleanded RXSOL-40-4090-025 to increase alkalinity in the water which results to form a protective film on METAL SURFACE.
Second Step  : Remove the corrosive oxygen from the water, either by mechanical or chemical deaeration Oxygen Scavenger RXSOL-50-5023-025. Excess of OXYGENT is mother of CORROSION.
Third Step       : Add corrosion inhibitors RXSOL-40-4011-025

Which material is used to protect COPPER METAL in Water System?

Copper Corrosion Inhibitors. The most effective corrosion inhibitors for copper and its alloys are the aromatic triazoles, such as benzotriazole (BZT) and tolyltriazole (TTA).

#CorrosionInhibitor_MultifunctionalClosedChilledSystems
#CorrosionInhibitor_ClosedChilledSystems
#CorrosionInhibitor_ClosedCoolingSystems
#BestCorrosionInhibitor_manufacturerSUPPLIERinDUBAIuae
#Corrosion-Inhibitor-Multifunctional-Closed-Chilled -ystems

Corrosion Inhibitor Multifunctional Closed Chilled Systems Manufacturer and supplier in India UAE Oman.
 

Closed System Corrosion Inhibitor for DPH ,  (Clear Pink Liquid , Spicific Gravity :1.160 , PH: 11.4 - 12.2,
Hashtags: 
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

Advantages: -

  • 1. Prolong the life of equipment by keeping scale and corrosion free. Since RXSOL-40-4011-256 is alkaline and so will suppress acid corrosion, which would otherwise result in corrosion damage such as pitting. However, the alkalinity control is such that even if the product is accidentally overdosed, the pH of the water will remain within limits. The metals which would be affected by extremes of alkalinity or acidity are protected.
  • 2. Improves generating cooling efficiency by maintaining a clean heat transfer
  • 3. Corrosion protection by using superior corrosion inhibitor.
  • 4. Reduced maintenance and down time
  • 5. Compatible with Coolants / Antifreeze solution / Glycol .
  • 6. Friendly with Metals (Like steel, Copper, Aluminum, all alloys) & Non-metal (Rubber, Hoses, Gasket etc.)

Corrosion Inhibitor Closed Cooling systems manufacturer and supplier in Mumbai, Kandla, Surat Gujarat, Chennai, Visakhapatnam, Kolkata, Haldia, Fujairah, Sharjah, Ajman, Mussafah Industrial Area Abu Dhabi, Abudhabi, Dubai, UAE Gulf, Ruwi Barka Muscat Oman, Nairobi Kenya, Sudan Yemen Canada

Alias: 
Industrial Area: 

Corrosion Inhibitor Multifunctional Closed Chilled Systems RXSOL-40-4011-025  manufacturer and supplier in Mussafah Industrial Area Abu Dhabi, Dubai, Sharjah, Ajman, Fujairah, United Arab Emirates. Corrosion Shield Protection chemicals for Cooling System available in UAE and supplier near by me in Mussafah Industrial Area Abu Dhabi, Dubai, Sharjah, Ajman, Fujairah, United Arab Emirates.
 

RXSOL CHEMICAL is one of the leading Scale and Corrosion Inhibitor Chemicals Manufacturers & Suppliers in UAE for Industrial, Oil Field and Marine Shipping Industries
 
In Cooling system,  Specialized Corrosion Inhibiotr gives atmosphere for Corrosion Protection, RXSOL is most popular leading manufacturer of environmentally-friendly corrosion inhibitors in  Middle East.
 
HOW CORROSION INHIBITOR WORKS AGAINST CORROSION in COOLING system?
 
Corrosion inhibitors are chemicals that can significantly reduce the corrosion of metals when Dose / applied as per guideline into the water and fluids.
Other Equivalent Brand: 

Accepta 2807, Korodex 8574, TRASAR TRAC 102, CORRSHIELD NT 4293, HYDREX 2853, Corrosion Inhibitor Multifunctional closed/chilled systems 30 Kg Ltr

Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates